Queensland Major Hazard Facility Safety Case or Hazardous Chemicals Manifest
Queensland major hazard facility (MHF) safety case outlines and safety cases under the Work Health and Safety Regulation 2011 (Qld) chapter 9 (ss 551-561, Schedule 18: facility description, process flow drawings, general layout drawings locating major incident hazards and initiators, security arrangements), and manifests of hazardous chemicals under s 347 and Schedule 12 (UN number, proper shipping name, class and division, container and storage area identification, after-hours contacts). Populated versions give a hostile reader a map of what is stored where and how the site is protected.
- Type
- regex
- Engine
- boost_regex
- Confidence
- medium
- Confidence justification
- Medium: the primary anchors are statutory terms that also appear in the Regulation, Safe Work Australia and WHSQ guidance, community information and blank manifest templates, so enforce tiers need populated Schedule 12 / Schedule 18 structure. 85/75 are heuristic evidence tiers, not measured accuracy; the test values are synthetic records laid out like Schedule 12 manifests and Schedule 18 safety case sections.
- Jurisdictions
- au
- Regulations
- Work Health and Safety Regulation 2011 (Qld)
- Frameworks
- QGISCF
- Data categories
- infrastructure, security
- Scope
- narrow
- Risk rating
- 8
- Platform compatibility
- Purview: Compatible, GCP DLP: Compatible, Macie: Compatible, Zscaler: Compatible, Palo Alto: Degraded, Netskope: Unsupported
Pattern
(?i)\b(?:major\s+hazard\s+facilit(?:y|ies)|MHF\s+(?:safety\s+case|licence)|safety\s+case\s+outline|manifest\s+of\s+hazardous\s+chemicals|hazardous\s+chemicals?\s+manifest)\b
Corroborative evidence keywords
security arrangements, unsupervised access, key register, major incident hazard, major incident initiator, process flow drawing, general layout drawing, CCTV, intruder alarm
Proximity: 300 characters
Should match
Pelican Point Ammonia Terminal (Teston Chemicals Pty Ltd) - major hazard facility safety case, section 4 security arrangements Storage area ID: SA-03 bulk ammonia UN number: 1005 Proper shipping name: AMMONIA, ANHYDROUS Class and division: 2.3 (8) Major incident hazards: loss of containment at tank T-201; unsupervised access to the jetty manifold is limited to six operators on the key register.— Safety case security section with populated Schedule 12 fields and security content (intended 85)Manifest of hazardous chemicals - Teston Fertilisers, Stapylton Date last amended: 02/09/2026 UN1942 | AMMONIUM NITRATE | 5.1 | Store B UN2067 | AMMONIUM NITRATE BASED FERTILIZER | 5.1 | Store C— Populated manifest table rows without security content (intended 75)Safety case outline - Teston Refinery MHF Drawing no.: PFD-1102 Rev C (crude unit) The draft emergency plan and a summary of the arrangements for site security are at Appendix D.— Safety case outline citing one populated drawing reference (intended 75)Hazardous chemicals manifest - Teston Water Treatment Plant (major hazard facility) Container identification: T-104 UN number: 1017 Proper shipping name: CHLORINE Class and division: 2.3 After hours contact: Jordan Teston 0491 570 156 Chlorine drum store has CCTV and an intruder alarm monitored off site.— Manifest for an MHF with container, UN and contact fields plus security content (intended 85)
Should not match
552 Content. A safety case outline provided under section 551 must include (e) a draft emergency plan and (f) a summary of any arrangements that are to be made in relation to the security of the major hazard facility.— Regulation text (legislation decoy, stays at 65)Manifest of hazardous chemicals Name of PCBU: __________ UN number: __________ Proper shipping name: __________ Class and division: __________ Storage area ID: [enter ID]— Blank manifest templateInformation for the local community - Teston Chemicals major hazard facility, Pinkenba Site address: 12 Wharf Road, Pinkenba QLD 4008 If you hear the site siren, go inside, close windows and listen to local radio.— Public s 572 community information leafletTraining exercise: complete a mock manifest of hazardous chemicals for a small depot. UN number: 1203 Proper shipping name: PETROL Class and division: 3— Training exerciseSECTION 14: Transport information UN number: 1942 Proper shipping name: AMMONIUM NITRATE Class and division: 5.1 SECTION 15: Regulatory information - Schedule 15 chemical; threshold applies for major hazard facilities.— Safety data sheet transport and regulatory sectionsQueensland has about 40 licensed major hazard facilities, including LPG depots, ammonium nitrate plants and refineries, the regulator said in a media release.— News / media release
Known false positives
- The Regulation, Safe Work Australia and WHSQ guides for major hazard facilities, and blank manifest templates. Mitigation: No populated field values; placeholders (blank lines, brackets, n/a, tbc) are rejected, and template/fixture framing is excluded.
- Public information for the local community (s 572) that names the facility and its address. Mitigation: The pattern-specific exclusion group removes local community information, fact sheets and media releases within the proximity window. An operator who pastes that leaflet text into a real safety case section loses the hit for that section only.
- Safety data sheets (section 14 transport information lists UN number, proper shipping name and class). Mitigation: SDS section headings (transport information, regulatory information, safety data sheet) are in the exclusion group.
- Dangerous goods transport documents at non-MHF sites. Mitigation: The primary requires an MHF, safety case outline or hazardous chemicals manifest anchor; placarding-only documents stay out.