Major outage root-cause analyses
Detects major outage root-cause analyses: RCA or post-incident review wording with populated outage fields and technical artefacts (incident/change numbers, hosts, timestamps). Topic wording alone is discovery-only.
- Type
- regex
- Engine
- boost_regex
- Confidence
- medium
- Confidence justification
- Medium confidence: the topic phrase alone is discovery-only; enforcement needs populated structure (a populated outage field (outage start/end/duration, impacted services, incident/problem/change number, severity) or a technical artefact (ServiceNow INC/CHG/PRB number, IPv4, internal hostname, timestamp)), and 85 needs two distinct structures plus independent RCA-outcome (contributing factors, corrective/preventive actions, lessons learned) evidence, so policies, blank forms and training text stay below 75.
- Detection quality
- Topic false positive
- Jurisdictions
- global
- Regulations
- Security of Critical Infrastructure Act 2018 (Cth)
- Frameworks
- ISO 27001, NIST CSF
- Data categories
- security
- Scope
- wide
- Risk rating
- 8
- Platform compatibility
- Purview: Compatible, GCP DLP: Compatible, Macie: Compatible, Zscaler: Compatible, Palo Alto: Degraded, Netskope: Unsupported
Pattern
(?i)\b(?:root[\s-]cause\s+analys[ie]s|RCA\s+(?:report|document|findings)|post[\s-]incident\s+(?:review|report)|post[\s-]mortem|major\s+(?:incident|outage)\s+(?:report|review))\b
Corroborative evidence keywords
contributing factor, corrective action, preventive action, customer impact, lessons learned, action owner, failover, rollback, detection, mitigation, SCADA, [object Object], [object Object], [object Object], Modbus, Modbus TCP, Modbus RTU, DNP3, OPC-UA, OPC Classic (+36 more)
Proximity: 300 characters
Should match
A root cause analysis will be circulated after the outage.— Discovery probe (65)Post-incident review Incident number: INC0041187 Duration: 3h 12m— Medium-tier probe (75) - populated outage fieldsMajor incident report - payroll outage Incident number: INC0041187 Outage start: 2026-09-12 07:02 Duration: 3h 12m Impacted services: payroll, rostering Change CHG0031542 rotated the certificate on lb01.harbour.internal; contributing factor: no rollback step. Corrective action owner: Infrastructure; lessons learned recorded.— High-tier probe (85) - several outage fields, artefacts and RCA outcome context
Should not match
unrelated generic text— No relevant phrase contextplaceholder value 12345— Random text should not matchPolicy statement: a root cause analysis is required for every priority 1 incident.— Policy textPost-incident review template Incident number: ________ Duration: [insert]— Blank templatePress release: the provider published its post-mortem after a four-hour outage on 12/09/2026.— News framing
Known false positives
- Public status-page post-mortems. Mitigation: News/press framing is excluded; enforcement needs populated outage fields or internal artefacts.
References
- Information Security Manual (ISM)
- Emergency management (Department of Home Affairs)
- Disaster Assist
- APP Guidelines Chapter 11: APP 11 Security of personal information
- NIST SP 800-61 Rev. 3: Incident Response Recommendations and Considerations for Cybersecurity Risk Management
- Security of Critical Infrastructure Act 2018 (Cth)